QSM202: Construction Measurement (2 of 4) Architectural and M&E Works, TMA 2, SUSS, Singapore

University Singapore University of Social Science (SUSS)
Subject QSM202 Construction Measurement Assignment

Question 1

Figures Q1.1 and Q1.2 show a gable roof plan with the roof rafter details.

(a) With reference to SMM clause 11.02b explain what is extreme sizes and net length. Calculate the extreme length of each rafter and the total quantities of the timber rafters required to construct the roof.

(b) Identify the relevant SMM clauses, explain and illustrate with appropriate diagrams the special considerations to keep in mind when measuring bearing timber members and plates that exceed 5.00 metres in length. Demonstrate the calculations involved with examples and give reasons for your answers.

QSM202: Construction Measurement (2 of 4) Architectural and M&E Works

QSM202: Construction Measurement (2 of 4) Architectural and M&E Works

Hire a Professional Essay & Assignment Writer for completing your Academic Assessments

Native Singapore Writers Team

  • 100% Plagiarism-Free Essay
  • Highest Satisfaction Rate
  • Free Revision
  • On-Time Delivery

Question 2

Figures Q2.1 to Q2.3 show the plan and sections of a hipped roof. Apply SMM rules and take-off quantities for the following works:

(a) Roof tile covering and the associated underlays.
(b) Ridge and hip capping, including the special eave courses.
(c) Structural timber including fascia boards .
(d) Eave boards including bearers.

Specifications:

  • Roof tiles shall be Hugenot HP 10 clay interlocking tiles with matching ridge, hip and eave tiles and fixed to 50 x 50 mm timber battens @ 300 mm c/c with galvanized nails. Pitch of roof is at 45 degrees.
  • Special tiles shall be required at ridges, hips and eaves of roof.
  • Roof underlay shall comprise of two layers of bitumen felt overall 10 mm thick.
  • Roof insulation shall be 50 mm thick fibre glass with double sided sisalation foil 450 and laid on fabric mesh 3325 to underside of roof covering
  • All roof timber shall be keruing preserved timber
  • Fascia board shall be 350 mm x 50 mm thick with halve joints for timber length exceeding 5.00 m long
  • All rafters and ridge board shall be 250 x 75 mm thick with scarfed joints. Rafters shall be spaced at 600 mm c/c.
  • Calcium silicate board shall be painted with 2 coats of emulsion paint

QSM202: Construction Measurement (2 of 4) Architectural and M&E Works

Buy Custom Answer of This Assessment & Raise Your Grades

QSM202: Construction Measurement (2 of 4) Architectural and M&E Works

QSM202: Construction Measurement (2 of 4) Architectural and M&E Works

Question 3

The Architect has selected a traditional timber panelled door based on the specifications provided by a manufacturer called Longden. The approved details are circled in the following figures:

Figure Q3.1 – Door Panel Style;
Figure Q3.2 – Fire Rating Of Door Panel
Figure Q3.3 – Door Styles
Figure Q3.4 – Door Component Typical Sections
Figure Q3.5 – Door Component Dimension Table

Identify the relevant SMM clauses and explain how fire rated timber door and door frame are measured and draft a complete description of the door based on the specifications given.

Stuck with a lot of homework assignments and feeling stressed ? Take professional academic assistance & Get 100% Plagiarism free papers

Get Help By Expert

Get expert assistance with QSM202: Construction Measurement (2 of 4) Architectural and M&E Works, TMA. Singaporean students can easily pay someone to do their assignment and get accurate Tutor Marked Assignment Answers. Our skilled professionals provide top-notch assignment help Singapore tailored to your course needs. Achieve better grades with our expert support!

Answer

Looking for Plagiarism free Answers for your college/ university Assignments.

Ask Your Homework Today!

We have over 1000 academic writers ready and waiting to help you achieve academic success