304SE Energy Systems Assignment: Boiler Efficiency & 3-Bus Power Flow Case Study with Carbon Emission Analysis, Singapore

University PSB Academy (PSB)
Subject 304SE: Power Systems

Question 1

A boiler generates 5000 kg of steam per hour. The specific enthalpy of the steam is 3600 kJ/kg and the specific enthalpy of the water supplied to the boiler is 300 kJ/kg. The calorific value of the fuel oil is 45 MJ/Kg.

  • Determine the amount of fuel oil supplied assuming the heat process is 70 % efficient.

(10 marks)

  • If the steam raised in the above example is supplied to the steam turbine and the enthalpy of the water steam mixture at the turbine outlet is 2700 kJ/kg. Determine the power output from the steam turbine. Assume the losses in the turbine amounts to 12 %.

(10 marks)

  • For 5000 kg/hr fuel used estimate the carbon emission per year for each fuel and Comment on the results obtained

Fuel A: Diesel with carbon emission factor 3.15 kg CO2/kg

Fuel B: Coal with carbon emission factor 2.4 kg CO2/kg

Note: Total carbon emission per year =Fuel consumption per year ×Carbon emission factor

(10 marks)

  • What are the benefits of replacing the fossil fuel mentioned in Q1.c with renewable source?

(10 marks)

[Total marks 40]

Hire a Professional Essay & Assignment Writer for completing your Academic Assessments

Native Singapore Writers Team

  • 100% Plagiarism-Free Essay
  • Highest Satisfaction Rate
  • Free Revision
  • On-Time Delivery

Question 2

A Three-bus power system is shown in Figure Q2.

Three-bus power system is shown in Figure Q2.

Figure Q2

The data for the buses are given in the Table Q2 A to E below.

Table Q2.A: Bus Data

Bus Number Bus voltage kV Initial pu set Remarks
BUS_1 66 1 Slack bus
BUS_2 66 1
BUS_3 66 1

Table Q2.B: Generator data

Gen Bus No. Reactance Min MW Max MW Min MVAR Max
MVAR
AGC AVR Enforce MW limits
1 1 0.01 0 2000 -9900 9900 YES YES YES

Table Q2.C: Line Data

Line Length Bus To bus Line parameters Remarks
1 10km 1 2 R= 0.005ohm /km

X= 0.001 ohm /km

B= 0 mho /km

 

 

Overhead line (line1), Admittance, Y is ignored in case of short transmission line
2 20km 1 3 R= 0.005ohm /km

X= 0.001 ohm /km

B= 0.001 mho /km

Underground cable (line2) Susceptance ,B refers to the capacitance of transmission line ,the B=  0.001 ohm /km
3 20km 3 2 R= 0.005ohm /km

X= 0.001 ohm /km

B= 0.001 mho /km

Underground cable (line3) Susceptance ,B refers to the capacitance of transmission line ,the B=  0.001 ohm /km

Table Q2.D: Load data

Load Bus number Real power(MW) Reactive power(MVAr)
1 2 1000 300
2 3 200 100

Buy Custom Answer of This Assessment & Raise Your Grades

Table Q2.E: Reactive power Compensator

Rating (MVAr) Bus Reactance
Shunt capacitor 200

 

2 0.1pu
  1. From The Network Details we find that Line 1,2 and 3 are using same type of cable with R= 0.005 Ω /km and X= 0.001 Ω /km, observe table Q2.C try to theoretical find the Rpu, Xpu and Bpu Comment on the pu values obtained.
    (5 marks)
  2. Follow the instructions given in Table Q2 B to D to construct the network using “Power World” software.
    NOTE: System base no changes applied default base MVA will be 100 MVA.
    All the field values such as voltage and phase angle at every bus and real and reactive power at both end of every line must be included in the circuit.
    The created network (before simulation) must be included in your report.
    (15 marks)
  3. From Tools menu choose solve and perform the Load Flow analysis. The simulated diagram with all the field values clearly shown must be included in your report.
    So to avoid black-out once the loads are added, start the load at 100MW and 100MVAr each slowly increase the load to the set value. Why do you think the variable loads are better handled by generator then a sudden huge load?
    (10 marks)
  4. Observe the transmission line loss for line 1 , 2 and 3 respectively without shunt capacitor , include simulation observation of V,P and Q loss on lines and provide theoretically analysis for voltage regulation of line 1 ,2 and 3. Suggest which line might need to be modified to improve the overall efficiency of the system.
    (10 marks)
  5. Repeat step C and D with Modified network by adding shunt capacitor and Include information of bus voltage and real and reactive power loss analysis for Modified network. Compare these results with those obtained in step C and D
    (20 marks)

 [Total marks 60]

Stuck with a lot of homework assignments and feeling stressed ? Take professional academic assistance & Get 100% Plagiarism free papers

Get Help By Expert

Do you need help with your 304SE Energy Systems Assignment Question? Our assignment help in Singapore is here for you! Whether you need someone to do my assignment for me or require report writing help, our Singapore experts are ready to help you with your Assignments. Singapore students can easily pay our experts for professional guidance with their coursework. Contact us today and get the best assignment help services from experienced writers.

Answer

Looking for Plagiarism free Answers for your college/ university Assignments.

Ask Your Homework Today!

We have over 1000 academic writers ready and waiting to help you achieve academic success