University | PSB Academy (PSB) |
Subject | 304SE: Power Systems |
Question 1
A boiler generates 5000 kg of steam per hour. The specific enthalpy of the steam is 3600 kJ/kg and the specific enthalpy of the water supplied to the boiler is 300 kJ/kg. The calorific value of the fuel oil is 45 MJ/Kg.
- Determine the amount of fuel oil supplied assuming the heat process is 70 % efficient.
(10 marks)
- If the steam raised in the above example is supplied to the steam turbine and the enthalpy of the water steam mixture at the turbine outlet is 2700 kJ/kg. Determine the power output from the steam turbine. Assume the losses in the turbine amounts to 12 %.
(10 marks)
- For 5000 kg/hr fuel used estimate the carbon emission per year for each fuel and Comment on the results obtained
Fuel A: Diesel with carbon emission factor 3.15 kg CO2/kg
Fuel B: Coal with carbon emission factor 2.4 kg CO2/kg
Note: Total carbon emission per year =Fuel consumption per year ×Carbon emission factor
(10 marks)
- What are the benefits of replacing the fossil fuel mentioned in Q1.c with renewable source?
(10 marks)
[Total marks 40]
Hire a Professional Essay & Assignment Writer for completing your Academic Assessments
Native Singapore Writers Team
- 100% Plagiarism-Free Essay
- Highest Satisfaction Rate
- Free Revision
- On-Time Delivery
Question 2
A Three-bus power system is shown in Figure Q2.
Figure Q2
The data for the buses are given in the Table Q2 A to E below.
Table Q2.A: Bus Data
Bus Number | Bus voltage kV | Initial pu set | Remarks |
BUS_1 | 66 | 1 | Slack bus |
BUS_2 | 66 | 1 | |
BUS_3 | 66 | 1 |
Table Q2.B: Generator data
Gen | Bus No. | Reactance | Min MW | Max MW | Min MVAR | Max MVAR |
AGC | AVR | Enforce MW limits |
1 | 1 | 0.01 | 0 | 2000 | -9900 | 9900 | YES | YES | YES |
Table Q2.C: Line Data
Line | Length | Bus | To bus | Line parameters | Remarks |
1 | 10km | 1 | 2 | R= 0.005ohm /km
X= 0.001 ohm /km B= 0 mho /km
|
Overhead line (line1), Admittance, Y is ignored in case of short transmission line |
2 | 20km | 1 | 3 | R= 0.005ohm /km
X= 0.001 ohm /km B= 0.001 mho /km |
Underground cable (line2) Susceptance ,B refers to the capacitance of transmission line ,the B= 0.001 ohm /km |
3 | 20km | 3 | 2 | R= 0.005ohm /km
X= 0.001 ohm /km B= 0.001 mho /km |
Underground cable (line3) Susceptance ,B refers to the capacitance of transmission line ,the B= 0.001 ohm /km |
Table Q2.D: Load data
Load | Bus number | Real power(MW) | Reactive power(MVAr) |
1 | 2 | 1000 | 300 |
2 | 3 | 200 | 100 |
Buy Custom Answer of This Assessment & Raise Your Grades
Table Q2.E: Reactive power Compensator
Rating (MVAr) | Bus | Reactance | |
Shunt capacitor | 200
|
2 | 0.1pu |
- From The Network Details we find that Line 1,2 and 3 are using same type of cable with R= 0.005 Ω /km and X= 0.001 Ω /km, observe table Q2.C try to theoretical find the Rpu, Xpu and Bpu Comment on the pu values obtained.
(5 marks) - Follow the instructions given in Table Q2 B to D to construct the network using “Power World” software.
NOTE: System base no changes applied default base MVA will be 100 MVA.
All the field values such as voltage and phase angle at every bus and real and reactive power at both end of every line must be included in the circuit.
The created network (before simulation) must be included in your report.
(15 marks) - From Tools menu choose solve and perform the Load Flow analysis. The simulated diagram with all the field values clearly shown must be included in your report.
So to avoid black-out once the loads are added, start the load at 100MW and 100MVAr each slowly increase the load to the set value. Why do you think the variable loads are better handled by generator then a sudden huge load?
(10 marks) - Observe the transmission line loss for line 1 , 2 and 3 respectively without shunt capacitor , include simulation observation of V,P and Q loss on lines and provide theoretically analysis for voltage regulation of line 1 ,2 and 3. Suggest which line might need to be modified to improve the overall efficiency of the system.
(10 marks) - Repeat step C and D with Modified network by adding shunt capacitor and Include information of bus voltage and real and reactive power loss analysis for Modified network. Compare these results with those obtained in step C and D
(20 marks)
[Total marks 60]
Stuck with a lot of homework assignments and feeling stressed ? Take professional academic assistance & Get 100% Plagiarism free papers
Looking for Plagiarism free Answers for your college/ university Assignments.
- RBP020L056 A Strategic Management Assignment Report: External & Internal Analysis with Strategic Options for Business Growth
- Capital Budgeting Assignment Report: PIONG Corporation Case Study on Risk & Investment Analysis
- BCAF003 Business Accounting Assignment : Temasek Polytechnic Case Study on Transactions, Equity & Trial Balance
- SM9532 International Expansion Strategy Assignment Report: CAGE, PND & AAA Analysis for Global Market Entry
- PSB6023CL Strategy and International Business Simulation Assignment Report: Automotive Case Study on Strategic Decision-Making and Performance Review
- ESG in Maritime Industry Assignment : Literature Review on Environmental, Social and Governance Practices
- CVE2332 Seepage and Flownet Analysis Assignment : Singapore River Cofferdam Case Study for Cost-Effective Sheet Pile Design
- DSWSH MC2 Electronic Security Assignment: Protection in Depth Plan for American International School (AIS) Singapore
- 6WBS0035/6 Digital Strategy Presentation Assignment: MNC Innovation Proposal for Global Growth
- PS6004EFA Project Assignment : Individual Research-Based Dissertation on Business and Management Topics