A2439C Clinical Laboratory Analysis Assignment: Antibody Assay, Diagnostic Accuracy & Slide Stainer Risk Evaluation, Singapore

University Republic Polytechnic (RP)
Subject A2439C Laboratory Management and Operations

Question 1 [13 marks]

Purified protein sample ‘X’ was used to plot a standard curve for an assay to measure antibodies in patients’ blood samples. Sample ‘X’ was serially diluted and absorbance was measured for each concentration (Table 1).

Table 1
Concentration of the stock solution (pg/mL) Volume of stock solution (µL) Volume of diluent (µL) Final concentration (pg/mL) Absorbance
1000 500 500 500 2.504
500 500 500 250 1.607
250 500 500 125 0.982
125 500 500 62.5 0.617
62.5 500 500 31.25 0.321
31.25 500 500 15.62 0.152
15.62 500 500 7.81 0.082
0 _ 500 0 0

a) Why was ‘0’ concentration of stock solution used in this test (last row)? Justify your answer. [3 marks]

b) Using the data from Table 1, plot a standard curve. [7 marks]

c) A patient’s blood sample was diluted 100 times and it produced an absorbance reading of 0.5. What is the concentration of antibody in the patient’s blood? [3 marks]

Hire a Professional Essay & Assignment Writer for completing your Academic Assessments

Native Singapore Writers Team

  • 100% Plagiarism-Free Essay
  • Highest Satisfaction Rate
  • Free Revision
  • On-Time Delivery

Question 2 [10 marks]

Test A is a gold standard method to determine disease ‘X’. Two other new test methods, B and C were compared with Test A. A method evaluation was done using Bland-Altman plots. The graphs are shown below.

a) Analyse the charts plotted and conclude if the new tests (Test B and C) are suitable to replace the gold standard (Test A). Provide relevant justifications for your conclusion. [6 marks]

Bland-Altman Plot showing the comparison between Test A and B

Figure 1: Bland-Altman Plot showing the comparison between Test A and B

Bland-Altman Plot showing the comparison between Test A and C

Figure 2: Bland-Altman Plot showing the comparison between Test A and C

b) It is reported that Test A has a sensitivity of 98% and specificity of 75%. Is Test A more suitable to be used as a screening test or as a confirmatory test? Justify your answer. [4 marks]

Question 3 [17 marks]

The following video shows the features of an automated slide stainer.

Laboratory XYZ, decided to purchase this slide stainer.

A. Outline the steps required to conduct a break-even analysis for these instruments. Discuss the importance of conducting break-even analysis before purchasing such devices. [4 marks].

B. State TWO analytical errors that might occur while using this instrument. Explain how to minimize them. [4 marks]

Buy Custom Answer of This Assessment & Raise Your Grades

C. Identify THREE work activities and draft a Hazard Identification and Risk Assessment (HIRA) document for the automated slide stainer. Please use the template provided below. [9 Marks]

 

Get Help By Expert

Do you need help with your Clinical Laboratory Analysis Assignment? Our assignment help in Singapore  is here for you! Whether you need someone to do my assignment for me or require report writing, our Singapore experts are ready to help you with your Assignments. Singapore students can easily pay our experts for professional guidance with their coursework. Contact us today and get the best assignment help services from experienced writers.

Answer

Looking for Plagiarism free Answers for your college/ university Assignments.

Ask Your Homework Today!

We have over 1000 academic writers ready and waiting to help you achieve academic success